author: Akbar Rahman
|
||||
date: \today
|
||||
title: MMME2047 // Turbomachinery
|
||||
tags: [ turbomachinery ]
|
||||
uuid: 11f0f745-2364-4594-8e47-127a4af39417
|
||||
lecture_slides: [ ./lecture_slides/T5 - Turbomachinery - with solutions.pdf ]
|
||||
lecture_notes: [ ./lecture_notes/turbomachinery lecture notes(H Power).pdf ]
|
||||
exercise_sheets: [ ./exercise_sheets/Turbomachinery-problems.pdf]
|
||||
---
|
||||
|
||||
Turbomachinery are rotating devices that add (pump for liquids; fan, blower, or compressor for gases at <0.02, <1 bar, and > 1 bar respectively) or extract (turbine) energy from a fluid.
|
||||
|
||||
# Positive Displacement (PD) Pumps
|
||||
|
||||
- PD pumps force fluid along using volume changes (e.g. bike pumps, the heart)
|
||||
- All PD pumps deliver a periodic flow
|
||||
- They deliver any fluid regardless of viscosity (dynamic pumps struggle with viscous fluids)
|
||||
- They are self priming (will be filled automatically)
|
||||
- They can operate under high pressures (300 atm) but low flow rates (25 m$^3$h$^{-1}$)
|
||||
- flow rate can be only be changed by vary speed or displacement
|
||||
|
||||
# Dynamics Pumps
|
||||
|
||||
- add momentum to fluid by fast moving blades or vanes
|
||||
- classified based on direction of flow at exit:
|
||||
|
||||
- centrifugal
|
||||
- axial
|
||||
- mixed flow
|
||||
|
||||
- fluid increases momentum while moving through open passages and extra velocity is converted to
|
||||
pressure through exiting it into a diffuser section
|
||||
- provide high flow rates (up to 70000 m$^3$h$^{-1}$) but usually at moderate pressure rises (a few atm)
|
||||
- require priming
|
||||
|
||||
# Centrifugal Pumps
|
||||
|
||||
- fluid enters through eye of casing and gets caught in impeller blades
|
||||
- fluid is whirled outwards until it leaves via the expanding area section, known as the diffuser or volute
|
||||
|
||||
## Blades
|
||||
|
||||
- backward inclined blades - most common and efficient, intermediate pressure rise, less robust
|
||||
- straight blades - simplest geometry, high pressure rise, less robust
|
||||
- forward inclined blades - more blades but smaller, lowest pressure rise, lowest efficiency, more robust
|
||||
|
||||
|
||||
## Integral Analysis of Centrifugal Pumps
|
||||
|
||||
Derivation in slides (p. 23-25).
|
||||
|
||||
\begin{align}
|
||||
\frac{w_s}{g} - \left(\frac{u_2-_1-q}{g}\right) = \left(\frac{p_2}{\rho g} + z_2 + \frac{v_2^2}{2g}\right) -\left(\frac{p_1}{\rho g} + z_1 + \frac{v_1^2}{2g}\right) \\
|
||||
H_s - H_f &= H = H_{T,2} - H_{T,1} \nonumber
|
||||
\end{align}
|
||||
|
||||
where $H_s$ is supplied head to pump, $H_f$ friction loss head, $H$ is head supplied to fluid, $H_{T,1}$ is total head at inlet, and $H_{T,2}$ is total head at outlet.
|
||||
|
||||
Assuming that $z_1 \approx z_2$, $v_1 \approx v_2$ (from inlet and outlet diameters are equal) then:
|
||||
|
||||
\begin{equation}
|
||||
H \approx \frac{p_2-p_1}{\rho g}
|
||||
\end{equation}
|
||||
|
||||
and the power to the fluid (water horsepower) is:
|
||||
|
||||
\begin{equation}
|
||||
P_w = \rho QgH
|
||||
\end{equation}
|
||||
|
||||
where $Q$ is volumetric flow rate.
|
||||
|
||||
Power supplied to the pump (brake horsepower), $P = \omega T$, lets us find the overall pump efficiency:
|
||||
|
||||
\begin{equation}
|
||||
\eta = \frac{P_w}{P} = \frac{\rho QgH}{\omega T} = \eta_h \eta_m \eta_v
|
||||
\end{equation}
|
||||
|
||||
where:
|
||||
|
||||
- $\eta_h = 1 - \frac{H_f}{H_s}$ is hydraulic efficiency
|
||||
- $\eta_m = 1- \frac{P_f}{P}$ is mechanical efficiency
|
||||
- $\eta_v = \frac{Q}{Q+Q_L}$ (where $Q_L$ is loss due to leakage flow) is the volumetric efficiency
|
||||
|
||||
## Performance
|
||||
|
||||
![](./images/vimscrot-2023-03-13T10:07:58,750255090+00:00.png)
|
||||
|
||||
# Cavitation
|
||||
|
||||
Cavitation is when bubbles form in liquid by sudden pressure drop, followed by their implosion when
|
||||
original pressure is restored.
|
||||
The implosion generates a high pressure wave that can damage nearby solid surfaces.
|
||||
|
||||
In a centrifugal pump, the fluid pressure drops at the impeller's eye, where it has the minimum
|
||||
value.
|
||||
If pressure falls below saturation pressure, bubbles appear.
|
||||
Pressure grows as the fluid flows between the blades as the ducts are diverging.
|
||||
Pressure is maximum at the trailing edge of the blades, on their front side.
|
||||
This is where cavitation occurs and causes wear on the blade.
|
||||
|
||||
<https://www.michael-smith-engineers.co.uk/resources/useful-info/pump-cavitation>
|
||||
<https://www.youtube.com/watch?v=g1o5Z9o7b0>
|
||||
<https://www.youtube.com/watch?v=eMDAw0TXvUo>
|
||||
<https://www.youtube.com/watch?v=1Lbxtjfdat4>
|
||||
|
||||
![](./images/cavitation.png)
|
||||
|
||||
# Net Positive Suction Head (NPSH)
|
||||
|
||||
The following conditions must be satisfied to prevent cavitation:
|
||||
|
||||
\begin{equation}
|
||||
H_i - \frac{p_v}{\rho g} > \text{NSPSH}
|
||||
\end{equation}
|
||||
|
||||
where $H_i = \frac{p_i}{\rho g} + \frac{v_i^2}{2g}$ is total head at inlet, $p_v$ is saturation
|
||||
pressure at $T_i$.
|
||||
|
||||
It is important that the inlet pressure is as high as possible.
|
||||
To do this, one can reduce frictional losses (e.g. shorter smoother pipes) or install the pump lower down
|
||||
(even below the reservoir) (slides p. 36).
|
||||
|